RE: Lateral water pressures on walls

[Subject Prev][Subject Next][Thread Prev][Thread Next]
There is no minimum.  Hydrostatic pressure on the walls at any depth, Y, is 62.4Y, no matter whether the planter is 1/2" or 1/2 mile wide.
JPRiley 
 
 
-----Original Message-----
From: Malik, Javed B. [mailto:MalikJB(--nospam--at)c-b.com]
Sent: Friday, April 23, 2004 9:04 AM
To: seaint(--nospam--at)seaint.org
Subject: Lateral water pressures on walls

For a hypothetical planter that is 50 feet long, one foot wide and 12 feet high, full of water and no drains, how do you calculate the lateral pressure on the long walls. I want to know the minimum width of planter at which full hydrostatic pressure will act.

Best Regards.

Javed Malik

 

This message contains confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secured or error-free as information could be intercepted, corrupted, lost, destroyed, received late or incomplete, or could contain viruses. The sender therefore does not accept liability for any error or omission in the contents of this message, which arises as a result of e-mail transmission. If verification is required, please request a hard-copy version from the sender.