Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

RE: SJ145

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Thanks,
 
bks
-----Original Message-----
From: THunt(--nospam--at)absconsulting.com [mailto:THunt(--nospam--at)absconsulting.com]
Sent: Wednesday, April 28, 2004 3:02 PM
To: seaint(--nospam--at)seaint.org
Subject: Re: SJ145


Brian,

According to the SJI specification adopted in August 20, 1929 and revised to June 1, 1948 an SJ145 has the following properties:

Depth (inch)                                14
Resisting Moment (inch-pounds)                156,000
Maximum End Reaction (pounds)        2,900
Safe Load (pounds per lineal foot)        180

Thomas Hunt, S.E.
ABS Consulting




"Brian K. Smith" <smithegr(--nospam--at)bellsouth.net>

04/28/2004 11:40 AM

Please respond to
<seaint(--nospam--at)seaint.org>

To
"Seaint" <seaint(--nospam--at)seaint.org>
cc
Subject
SJ145





Can anyone give me the capacity of an SJ145 spanning 24' built in 1948.
 
 
 
bks