RE: 1 1/8" sht'g. diaphragm values

[Subject Prev][Subject Next][Thread Prev][Thread Next]
<Sorry for the potential double post -- I got a message saying my
original message was blocked by a spam filter>

Diaphragm table in building code states "minimum nominal panel
thickness" (and requires minimum nail penetration).  So, for 1-1/8"
sheathing, use either 15/32" Str. I numbers or 19/32 sheathing numbers
(turns out they are the same numbers).  And make sure nail is long
enough to provide 1-1/2" penetration (1-5/8" for older building codes).
 
Tom
 
----------------------------------------------------------------------- 
Thomas D. Skaggs, Ph.D., P.E. 
Senior Engineer 
APA - The Engineered Wood Association 
7011 S. 19th Street 
Tacoma, WA 98466 
ph: 253/565-6600 
fx: 253/620-7235 
----------------------------------------------------------------------- 

________________________________

From: Mark D. Baker [mailto:shake4bake(--nospam--at)earthlink.net] 
Sent: Thursday, April 29, 2004 14:13
To: seaint(--nospam--at)seaint.org
Subject: 1 1/8" sht'g. diaphragm values


 
Can anyone direct me to diaphragm shear values for 1 1/8" sht'g.?
 
TIA
Mark


Mark D. Baker
President
Baker Engineering
	
732 Encino Place
Santa Paula CA 93060 
V-805-525-3658
F-805-525-4958


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********