No, we don't.  It has fascinated me that other jurisdictions take building so seriously as to require checking by an agency, or peer review.  In Quebec, there is no such thing.  Most Building Departments here don't even want to see the structural drawings.  Whenever a certificate or whatever is required, it is blindly accepted if signed by an engineer.
 
 

Kevin Below, ing., Ph.D.

GÉNÉCOR CIVIL INC.

290, rue Seigneuriale

Beauport, (Québec) G1C 3P8

Tél. : (418) 660-6969 poste 272

Fax : (418) 660-6463

-----Original Message-----
From: Stanley E Scholl [mailto:sscholl2(--nospam--at)juno.com]
Sent: 26-May-04 00:41
To: seaint(--nospam--at)seaint.org
Subject: Re: Are wood shearwalls going out of fashion, or what ?

Don't you have structural plan check in this agency- by a qualified engineer? 
 
Stan Scholl, P.E.
Laguna Beach, CA
 
On Tue, 25 May 2004 21:53:10 -0400 Kevin Below <kevinbelow(--nospam--at)videotron.ca> writes:
It looks I will be replaced as engineer on a series of condo buildings in the province of Quebec, because my design incorporates anchorages, holddowns, and - heaven forbid - OSB panels on several interior partitions, as well as the perimeter walls.  I even specified nail spacings and other untofore-seen inanities.
The sub-contractor for the walls and (Hambro) joists had never seen that sort of thing before.  So he offered the services of his usual engineer, who told my client that these unnecessary items would cost about $100,000.  The client says he's confused, and he'll have to go with the engineer who saves him the most money.
 
So, I guess it pays to be ignorant.  That engineer, I deduce, has probably not changed his methods from the days (about 15 years ago), when bracing for wood-frame buildings here was automatically simply a plywood panel at each end of each main exterior wall (a total of 8 panels per storey).  But this building is 4 stories, and has lots of wide openings in the end walls (sliding doors and windows on about 70 %).  It is hopelessly inadequate without interior partitions as shear walls, in both directions.
 
Oh well, I'll get over it.  I may have to call the Ordre des Ingénieurs, because the public safety is involved.
 
Losing those contracts will give me more time to seek out clients with a little more scruple.
 

Kevin Below, ing., Ph.D.

GÉNÉCOR CIVIL INC.

 

---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.686 / Virus Database: 447 - Release Date: 2004-05-14

 

---
Incoming mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.686 / Virus Database: 447 - Release Date: 2004-05-14


---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.686 / Virus Database: 447 - Release Date: 2004-05-14