Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

Re: Bar Joists parallel to masonry walls

[Subject Prev][Subject Next][Thread Prev][Thread Next]
I use them in both 8 and 12" walls. The web is placed into the head joint with the flange on the outside of the CMU. There are also headed studs for pullout resistance.
Regards,
Harold Sprague


From: Jnapd(--nospam--at)aol.com
Reply-To: <seaint(--nospam--at)seaint.org>
To: seaint(--nospam--at)seaint.org
Subject: Re: Bar Joists parallel to masonry walls
Date: Mon, 16 Aug 2004 22:20:36 EDT

Harold:

DO you use this WT in 8 or 12 " walls ?
Is the flange face up as a "T" in section and does the flange get in the way
of the next course ?

Joe Venuti
Johnson & Nielsen Associates
Palm Springs,  CA