Boundary elements in shearwalls

[Subject Prev][Subject Next][Thread Prev][Thread Next]
According to ACI 99-21.6.6 the requirements for boundary elements are in reference to "special reinforced concrete walls". I am in SDC C and am using ordinary reinforced concrete walls as allowed by IBC table 1617.6.

Does this mean that I can ignore the need for boundary elements since I am not designing a "special" wall, even if my factored forces exceed 0.2f'c? It doesn't really seem correct to ignore them.