Hi Glen.
 
I thought I might have an answer for you, but I don't have experience with the IRC reference.  I would, however, suggest that simple lapping of floor joists would not, of itself, constitute lateral restraint (to joist roll).
 
I am open to correction though.

Thor A. Tandy P.Eng
Victoria, BC
Canada
vicpeng(--nospam--at)telus.net
----- Original Message -----
From: Glenn Otto
Sent: Wednesday, October 27, 2004 7:59 AM
Subject: Wood - Lateral Bracing

(By request, I am resending the original)

List,

Does the lapping of floor joists over interior supports of IRC R502.6.2
constitute lateral restraint of R502.7?  I think it does according to the
cartoon of Figure R502.2, but I can't find anything else that supports that.

Also, I use unbraced length = 1 ft (gravity) when I have floor or roof
sheathing.

Thanks,.
Glenn C. Otto, P.E.
A Structural Engineer
Virginia Beach, VA