Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

Re: LRFD Manual Ex 5.1 page 5-12 to 5-16

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Hi,

On page 5-21, of example 5.3, should the phi_b*M_px = 506 kip-ft
instead or 398 kip-ft?  Table 5-2 on page 5-40 has 506 in the table.
It is not covered in corrections by AISC.

Sam


On Fri, 7 Jan 2005 07:55:55 -0500, Wesley Werner <wwerner(--nospam--at)conewago.com> wrote:
> See below.
> 
> 
> 
> Wesley C. Werner
> 
> 
> -----Original Message-----
> From: Szuchuan Chang [mailto:szuchuan(--nospam--at)gmail.com]
> Sent: Friday, January 07, 2005 12:39 AM
> To: seaint(--nospam--at)seaint.org
> Subject: LRFD Manual Ex 5.1 page 5-12 to 5-16
> 
> 
> Hi,
> 
> AISC LRFD 3rd ed. (first print) has a basic steel beam design strength
> example 5.1 on a braced; 1/3 points braced; and ends brace only conditions.
> 
> On page 5-13,  the shear capacity should be multiplied by 0.6 according with
> Eq F2-1 (see page 16.1-35) which becomes 152.2 kips instead of 254.  Is that
> correct? 152. kips is correct. This item carries on 4
> places in this example.
> 
> On page 5-14, the Rho(b)M(r) is 205 kip-ft.  However, numbers used in Eq
> F1-2 is 250.  Is that a typo?  When I run the numbers, I get 205 kip-ft
> 
> On page 5-15, the 2*(L(b)/r(y)) inside the square root should be squared.
> While I can't find it in the errata, you appear to be correct.
> 
> Is there an errata site for these kind of questions?
> 
> thanks
> 
> Sam
> 
> ******* ****** ******* ******** ******* ******* ******* ***
> *   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
> *
> *   This email was sent to you via Structural Engineers
> *   Association of Southern California (SEAOSC) server. To
> *   subscribe (no fee) or UnSubscribe, please go to:
> *
> *   http://www.seaint.org/sealist1.asp
> *
> *   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
> *   send to the list is public domain and may be re-posted
> *   without your permission. Make sure you visit our web
> *   site at: http://www.seaint.org
> ******* ****** ****** ****** ******* ****** ****** ********
>

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********