RE: Concrete Pile Cap to Steel Pile Load Transfer

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Thanks again - between this and the Wheeling Joists, I figure we're up
to a case and a half. 

-----Original Message-----
From: Harold Sprague [mailto:spraguehope(--nospam--at)hotmail.com] 
Sent: Wednesday, March 16, 2005 1:35 PM
To: seaint(--nospam--at)seaint.org
Subject: RE: Concrete Pile Cap to Steel Pile Load Transfer

Re: The Steel Pile Cap Connection, AISI, August 1982.

Confined concrete is different than unconfined.

Conclusions from the reference above:
Steel cap plates are not required for steel H piles in compression with
proper embedment and edge distance and is the most economical solution
Embedment 6 inches min Edge dist 12 to 21 inches depending on pile
capacity Ult bearing stress is 8 * f'c Ult bearing stress is 10 * f'c
with some supplementary reinforcement in the cap

Some piles tested to an ult bearing stress of 41 ksi for f'c = 3.68 ksi
concrete.

That will cost you 2 beers and a shot.

Regards,
Harold Sprague




>From: "Brian S Bossley" <BSBossley(--nospam--at)venturaengineering.com>
>Reply-To: <seaint(--nospam--at)seaint.org>
>To: <seaint(--nospam--at)seaint.org>
>Subject: Concrete Pile Cap to Steel Pile Load Transfer
>Date: Wed, 16 Mar 2005 11:19:05 -0500
>
>
>Does anyone know how a large capacity (100 Ton) steel pile transfers 
>the load in bearing to a concrete pile cap?  I have an HP12x53 pile w/ 
>an area of 15.5 in^2 and I've got 12.9 ksi in the steel, but I know 
>that concrete can't take those kind of stresses.
>
>Brian S. Bossley, PE
>Ventura Engineering
>7610 Olentangy River Rd.
>Columbus, OH 43235
>(614) 847-1110 x121

_________________________________________________________________
Don't just search. Find. Check out the new MSN Search! 
http://search.msn.click-url.com/go/onm00200636ave/direct/01/


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ******** 

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********