RE: 10J2 loading criteria - 1970 era

[Subject Prev][Subject Next][Thread Prev][Thread Next]
From page 185 of the 50 year digest, the allowable load for a 10J2 with a 12' span is 324 plf.  The load is governed by flexure, not by shear.
 
Moment capacity - 70,000 in-lb
Max. end reaction - 2000#
weight - 4.2 plf
-----Original Message-----
From: Terry Triest [mailto:tatriest(--nospam--at)hayeslarge.com]
Sent: Thursday, April 07, 2005 4:21 PM
To: seaint(--nospam--at)seaint.org
Subject: 10J2 loading criteria - 1970 era

Could someone send me the loading criteria for a 10J2 at 12'-0" clearspan?  I am missing pages 184 & 185 of the SJI historical reference manual.
 