RE: Connections Designing, General Standards? POLL

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Refugio,

It seems like you have answered your own concerns.

For me, it really depends on the client and the project.  I prefer to limit
materials to a couple of sizes whenever possible, for example: a large bolt
and a small bolt, a large column and a small column, etc.  As, this limits
confusion in the field, it may not always be the most practical solution.

Sharon

-----Original Message-----
From: refugio rochin [mailto:fugeeo(--nospam--at)gmail.com]
Sent: Friday, May 27, 2005 10:48 AM
To: seaint(--nospam--at)seaint.org
Subject: Connections Designing, General Standards? POLL


I am wanting to take a poll.

How many engineers design to the load
and how many engineers design to the member
strength?

For instance, if so much shear at a connection
is much lower than shear capacity, how many
would still design to the shear capacity of the beam,
and how many would design only to the requirement
of the structure?

Asking, what is general opinion on this matter?

Seems if there is a general design to a member,
then many connections could be prequalified,
and there becomes no real need to go through
muliple calcs to find an adequate connection detail.

Perhaps if the structure is a facility that may change,
ie. have future load changes as in a hospital, then
these pre-connections could be very valuable.  Whereas
in a small building, it is better to save on the connection
value.

At the same time, are connections so costly that designing
to the load, versus the member would save so much?

Regards
Refugio

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********