Actually, this does a great job preventing torsion, as the plate covers the entire top flange. If the supporting beam rotates away, the point of contact is the far flange, providing a restoring force (but increasing the moment in the plate and across the weld).  If the supporting beam rotates toward the supported beam, the point of contact (And force) shifts to the near flange. This side is also limited by the bottom flange of the supported beam, but that could result in a nasty service condition for a highly-active live load (clunk-clunk-clunk).

Tom Barsh @ Codeware wrote:
One possible problem is that the supporting beam may be loaded slightly eccentrically, leading to some torsion acting on the beam. Even worse is that the connection detail doesn't provide much resistance against the supporting beam rotating about its axis (bottom flange kicking out). But this could be addressed by field welding (or bolting) an angle to the webs of the two beams
 
 

******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********