Matthew,

A722 is 150 ksi rebar with no requirements on hardness. I would be concerned about the potential for hydrogen embrittlement for the galvanized A 722 bar. Hard galvanized steels have long been a concern for hydrogen embrittlement.

Regards,
Harold Sprague





From: "Stuart, Matthew" <mstuart(--nospam--at)schoordepalma.com>
Reply-To: <seaint(--nospam--at)seaint.org>
To: <seaint(--nospam--at)seaint.org>
Subject: A 722 high strength steel bars
Date: Mon, 22 Aug 2005 13:52:12 -0400

Is anyone aware of any restrictions on galvanizing A722 high strength steel bars?