I am going to be using an omf with a WUF-B moment connection in a two story
wood framed residential project designed per FEMA 350. 97 UBC is in effect
here. Please correct the following if wrong:

 

Member design will be per load combinations of section 1612.3.1 of 97 UBC.,
no 1/3 incr. 

Columns checked per 2213.5.1 of 97 UBC.

Joint designed per 3.5.1.1 of FEMA 350 for Plastic Moment + contribution
from shear of beam gravity loads considering location of plastic hinge.

Beam gravity loads should be strength level, ie.1.2D+.5L.

 

When designing the joint per FEMA 350, UBC section 2213.6 item 2 (design
strength of connection capable of resisting combination of gravity loads and
omega times seismic) is not applicable..correct?

 

Thanks in advance.

 

Mark

 



 