RE: ASCE 7-02: Live Load on Canopy

[Subject Prev][Subject Next][Thread Prev][Thread Next]
The 'Marquees' listing does not include other items and still requires a
uniform load of 75-lb/sf. 

Nels Roselund, SE
South San Gabriel, CA
njineer(--nospam--at)att.net

-----Original Message-----
From: David Merrick [mailto:MRKGP(--nospam--at)winfirst.com] 
Sent: Wednesday, March 08, 2006 9:40 AM
To: SEAINT
Subject: Re: ASCE 7-02: Live Load on Canopy



ASCE 7-05 table 4-1, page 13
Live load is 5psf or 20 psf
Fabric...rigid skeleton... 5psf
All other... 20 psf

-- 
David B. Merrick, Structural Engineer
 



******* ****** ******* ******** ******* ******* ******* ***