Whoever produced the structural drawings is responsible for marking the TOC elevation on the drawings. Period. As a steel detailer, you are not responsible for it. If anyone has to worry about it, it will be the construction supervisor. You  are only responsible for producing shop detail drawings based on the structural drawings provided to you. If dimensions are missing in the structural drawings, ask for those details.

Force the engineer/architect for elevation data, if it is material for your work. As a conscientious engineer, you may want to alert the engineer/architect regarding construction problems because of the lack of elevation data on his drawings.

I suspect that the engineer/architect was the lowest bidder on the project and he did not include any money in his estimate for field survey. During detailed design phase, confronted with this issue, he might have wished away the problem by including a few stupid notes on the drawings.

Rajendran

G Vishwanath <gvshwnth(--nospam--at)yahoo.com> wrote:
Who decides top of concrete Level?

We are detailing an apartment building.
There is a floor supported on steel beams very close
to the base plate level of the columns.
Neither the bottom of base plate level nor top of
concrete level is explicitly indicated.
Instead a detail in the Structural dwg indicates the
top of concrete level as "minimum 6" below the bottom
flange of the steel beams.

This should have been easy.

Except that the beams vary in depth from a minimum of
14" to a maximum of 30"
So what do we do?
Consider the deepest of them (30") and keep the the
top of concrete level at 36" uniformly for all?
Or go hopping all over the place and have different
top of concrete levels for each case?
We sent an rfi requesting the engineer to indicate the
top of concrete levels to be considered.
The engineer answers our rfi by simply quoting the
detail that we have already seen and are not satisfied
with.

Since when is the top of concrete level being decided
by the steel detailer.
Indicating minimum 6" passes the buck to us.
How will the foundation construction be done?
Will they refer to steel dwgs?

At some other places the engineer says "keep top of
concrete at least 4" below sidewalk level. Coordinate
with Arch dwgs"

What does at least 4" mean?
Again the buck is being passed on to us?

We looked up the Arch dwgs.
An elevation of the building is shown.
The ground level varies haphazardly.
The slopes are not uniform and vary along the length
of the building.
The ground slope is also not uniform.
Are we to decide the sidewalk levels from this ?

I have misgivings about this project.
Any experiences to share?
Any opinions or advice is welcome.
Regards
Vish


__________________________________________________
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around
http://mail.yahoo.com

******* ****** ******* ******** ******* ******* ******* ***
* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
* This email was sent to you via Structural Engineers
* Association of Southern California (SEAOSC) server. To
* subscribe (no fee) or UnSubscribe, please go to:
*
* http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
* send to the list is public domain and may be re-posted
* without your permission. Make sure you visit our web
* site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********


New Yahoo! Messenger with Voice. Call regular phones from your PC and save big.