Our standard detail for a wastewater tank wall is to provide a starter wall on the slab with a key and PVC waterstop in the joint.  The contractor has proposed an inverted key using 1x4 form attached to the inside of the vertical rebar with a PVC waterstop at the top of the key.  My concern with this method is that the base of the key is at the slab/wall interface.  If the key were to crack at the slab (where the bottom of the joint is located), there would be a potential water path because the water stop would be above the crack.  Has anyone used the inverted key and have there been any problems?

 