RE: Seismic tank design

[Subject Prev][Subject Next][Thread Prev][Thread Next]
David,
What seismic zone is the tank in?  In zone 4, the diameter generally has to
be at least two times the height in order to make it work without a concrete
foundation and anchor bolts.  What code or specification was it designed by?
The best things are AWWA D100 if for water or API 650 App. E if oil or
chemical.  With regard to the soil, I think you have to assume one KSF
unless they have a soils report with higher values.
Richard Hess

-----Original Message-----
From: David Merrick [mailto:MRKGP(--nospam--at)winfirst.com]
Sent: Tuesday, April 11, 2006 1:28 PM
To: SEAINT
Subject: Seismic tank design


I am reviewing a pipe line that connects, at the base, tanks of 24 feet
dia and 16 feet high.
The designer reports a seismic 1.3" uplift.
The steel tank shell  and steel floor plate sit on 6" of 3/4"max well
graded rock over a "compacted fill pad" The soils are clays in a flood
plane.
The analysis does not check soil bearing and shear. There is no estimate
of lateral sliding.

I am concerned that the soils are assumed to have a 2500 psf capacity
for the central roof column footing.

Should the movement at the tank to pipe include not only a factored
uplift but also some sliding?

Should not have the tank foundation been checked for overturning bearing?


--
David B. Merrick, Structural Engineer


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********


--
No virus found in this incoming message.
Checked by AVG Free Edition.
Version: 7.1.385 / Virus Database: 268.4.1/308 - Release Date: 4/11/2006



******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********