Joe:
My understanding is that the force has to be scaled back to the value of 4.5 (and then multiplied by Omega.)

L.C.


--------------------------------------------------------------------------------

From: Jnapd(--nospam--at)aol.com [mailto:Jnapd(--nospam--at)aol.com]
Sent: Friday, May 05, 2006 8:32 AM
To: seaint(--nospam--at)seaint.org
Subject: Re: collector design in wood frame structures

Eliseo:

The conservative answer.....R for structure changes from 5.5  to 4.5.

Non-conservative use .....R is still 5.5, light frame wood structure exemption.