RE: Wind loading with axial forces on steel studs

[Subject Prev][Subject Next][Thread Prev][Thread Next]
I always thought you could only use main frame pressures when your tributary
area was large enough.  I have designed load bearing steel stud walls and
wood stud walls with components and cladding pressures and have spread sheets
to figure the pressure based length and spacing.

-----Original Message-----
From: Terangue Gillham [mailto:tiger(--nospam--at)palaunet.com] 
Sent: Monday, June 05, 2006 2:36 PM
To: seaint(--nospam--at)seaint.org
Subject: RE: Wind loading with axial forces on steel studs

Maybe this is too simplistic, but doesn't it just depend on the TA for the
member?  If that is the case, would the higher (localized) pressures be used
for face loading, but lower (MWFRS) pressure be used for axial load?

Terangue *Tiger* Gillham, PE
GK2, Inc.

tiger(--nospam--at)palaunet.com <mailto:tiger(--nospam--at)palaunet.com>


-----Original Message-----
From: Drew Morris [mailto:dmorris(--nospam--at)bbfm.com]
Sent: Tuesday, June 06, 2006 3:58 AM
To: SEAINT
Subject: Wind loading with axial forces on steel studs


I have it in my mind that when you are looking at combined loading on wall
studs (wind pressure and axial loads), you don't have to use the C&C
pressures, but the MWFRS pressures.  I have been going through ASCE
7-02 to verify this but can't find it.  I remember Buddy Showalter explaining
this for wood studs walls, does it appply to steel stud walls also?



******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********



******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ******** 

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********