Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

Lag bolt value from NDS Report 12

[Subject Prev][Subject Next][Thread Prev][Thread Next]

Maybe our favorite AWC guy is out there, but maybe someone else out there can answer this question.

 

I am looking at a lag bolt value and I am using Technical Report No. 12 from AWC.

 

Per footnote 2 on Table 1, Ms and Mm both use Fb,pl in the equation for yield modes IIIm, IIIs, and IV.  The example on page 10 uses Fb,5% or at least that is what is shown as used (I haven’t worked through the examples).  Is the footnote incorrect, or the example or (I suppose it could happen) am I missing something?

 

Thanks,

Joe

 

Joseph R. Grill, P.E. (Structural)

Shephard - Wesnitzer, Inc.

Civil Engineering and Surveying