Gerard,

I had similar thoughts when I saw some of those photos from the link that
Steve provided.  Those seemed like two (in the pictures that I saw)
awfully small epoxy anchors compared to some rather beefy Tee-sections,
hanger rod and clevises.

Regards,

Scott
Adrian, MI


On Fri, 14 Jul 2006, Gerard Madden, SE wrote:

> Look at those 4 dinky bolts MAYBE 6" long total holding a thick WT with huge
> clevis.... no wonder.
>
> -g
>
> On 7/14/06, Paul Feather <PFeather(--nospam--at)se-solutions.net> wrote:
> >
> >  Looks like the entire epoxy plug pulled clean with inadequate bond to the
> > concrete, not the bolts pulling clean without epoxy on them.
> >
> >
> >
> > Paul Feather PE, SE
> >
> > pfeather(--nospam--at)SE-Solutions.net
> >
> > www.SE-Solutions.net
> >
> >
> >   ------------------------------
> >
> > *From:* S. Gordin [mailto:mailbox(--nospam--at)sgeconsulting.com]
> > *Sent:* Friday, July 14, 2006 11:56 AM
> > *To:* seaint(--nospam--at)seaint.org
> > *Subject:* Re: big dig structural failure - epoxy anchors overhead
> > supporting gravity
> >
> >
> >
> > Paul,
> >
> >
> >
> > This is exactly how it looks.
> >
> >
> >
> > http://www.militaryphotos.net/forums/showthread.php?t=85890
> >
> >
> > http://www.boston.com/news/traffic/bigdig/articles/2006/07/12/workmanship_and_design_of_tunnel_are_called_into_question/?p1=MEWell_Pos5
> >
> >
> >
> > Steve Gordin SE
> > Irvine CA
> >
> >  ----- Original Message -----
> >
> > *From:* Paul Feather <PFeather(--nospam--at)se-solutions.net>
> >
> > *To:* seaint(--nospam--at)seaint.org
> >
> > *Sent:* Friday, July 14, 2006 9:10 AM
> >
> > *Subject:* RE: big dig structural failure - epoxy anchors overhead
> > supporting gravity
> >
> >
> >
> > <...> If the report is that the epoxy bolts pulled "clean out", it is most
> > likely the holes were not properly cleaned of drill dust and latent material
> > and the entire piece separated cleanly, bolt with epoxy and all.
> >
> >
> >
> > Paul Feather PE, SE
> >
> > pfeather(--nospam--at)SE-Solutions.net
> >
> > www.SE-Solutions.net
> >
> >
> >
> >
>
>
> --
> -gm
>

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********