RE: existing wood floor joist bending stress

[Subject Prev][Subject Next][Thread Prev][Thread Next]

If this is simply a removal and replacement of flooring, you can use the values from the original design.  If there is new construction involved (ie. adding framing for an opening), then you might consider checking the existing joists based on newer code values.

 

HTH,

 

Doug Mayer, S.E.

Structural Engineer

teter a+e, LLP

Architects & Engineers

p: 559.437.0887

f:  559.438.7554

e: dougm(--nospam--at)teterae.com

w: www.teterae.com


From: ESG Design [mailto:esgdesign(--nospam--at)gmail.com]
Sent: Wednesday, September 06, 2006 11:25 AM
To: seaint(--nospam--at)seaint.org
Subject: Re: existing wood floor joist bending stress

 

The best thing to do would be to remove one of the joists and do an actual load test and record the bending capacity.  The other numbers you mentioned are slightly arbitrary in reality.

On 9/6/06, Joseph Eribarne <jeribarne(--nospam--at)bak.rr.com> wrote:

I am involved with a structure that was constructed in 1988.  2x12 floor
joists were designed for a tile flooring weighing 30psf.  The allowable
bending stress for a repetitive Doulas Fir Larch joist was 1450 psi in the
1988 UBC.  A flooring weighing 3 psf was applied (to save money).

The client would now like to apply a flooring weighing 10 psf, substantially
less that the original design.  However, the present day code indicactes
that the allowable bending stress for this wood is now 1006 psi.  The design
bending stress in the joist with the 10psf flooring is 1200 psi.  What is
the allowable bending stress for the joist in the existing structure?  Is it
the origial 1450 psi, resulting in a design stress of 83% of capcity or is
it 1006 psi, resulting in a 19% overstress, or is it something else?

Thank you for your attention.

Joseph Eribarne


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********




--
~ ESG DESIGN ~
---------------------------
eli s. grassley, p.e.