Bill,
In this area of Canada, (not shakey), normal practise is partially grouted or ungrouted using 6", 8", 10" and 12" block. The new code versions are just being issued and I am told that ungrouted construction will be more restricted. Steel angle and wide flange lintels are popular as masons can just keep going. Block is used widely for single and up to say 12 or so storey apartment buildings, also some commercial and industrial buildings. Spacing of control joints has varied widely with some archies not even specifying them but the usual max has been 30 ft although I am now using 24' max or Z times the thickness whichever is smaller. Big problem here is a shortage of experienced masons so that delivery times are long and masons are getting good bucks. My 2 cents worth.
Gary
Niagara Falls, Ontario

William.Sherman(--nospam--at)CH2M.com wrote:
I am interested in variations in regional practices for masonry
construction, especially in the US and Canada. As noted below, there are
some variations in practice regarding fully grouted vs partially
grouted.  Are there other variations in regional practices: types of
block typically used or available? mortar types commonly used? use of
lintel blocks vs steel lintel beams? single wythe usage? variations in
control joint types and spacing?

Bill Sherman
CH2M HILL / DEN 720-286-2792
-----Original Message-----
From: Harold Sprague [mailto:spraguehope(--nospam--at)hotmail.com] Sent: Tuesday, September 26, 2006 8:42 AM
To: seaint(--nospam--at)seaint.org
Subject: RE: Masonry in Las Vegas Fully Grouted or Partially Grouted

That reinforces what I just heard from a friend at NCMA.  California and
most of Nevada is almost exclusively fully grouted.  Oregon and
Washington is more mixed between fully grouted and partially grouted.
Everywhere else, the tendency is for partially grouted unless there is a
definitive reason to require fully grouted.  I like to use what is
standard in a given industry if possible.

Regards,
Harold Sprague

From: "Paul Feather" <PFeather(--nospam--at)se-solutions.net>
Reply-To: <seaint(--nospam--at)seaint.org>
To: <seaint(--nospam--at)seaint.org>
Subject: RE: Masonry in Las Vegas Fully Grouted or Partially Grouted
Date: Mon, 25 Sep 2006 16:15:49 -0700

Harold,

My experience has been that fully grouted walls are the standard in Las

Vegas.

Paul Feather PE, SE
pfeather(--nospam--at)SE-Solutions.net
www.SE-Solutions.net

-----Original Message-----
From: Harold Sprague [mailto:spraguehope(--nospam--at)hotmail.com]
Sent: Monday, September 25, 2006 2:55 PM
To: seaint(--nospam--at)seaint.org
Subject: Masonry in Las Vegas Fully Grouted or Partially Grouted

What is the tendency for reinforced CMU walls in the Las Vegas area?

I know in California, the convention is to use fully grouted reinforced

CMU walls. In most other areas of the US, the convention is to use partially grouted reinforced CMU walls.

What is the convention in the Las Vegas area for reinforced CMU walls?
Fully grouted or partially grouted?

Regards,
Harold Sprague

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********