Driveway surcharge on retaining wall

[Subject Prev][Subject Next][Thread Prev][Thread Next]

I am looking at a short, 4 ft to 5 ft retaining wall that is on a property line.  The property line is on the heel side of the wall, therefore there is no heel at the footing.  Also, there will be a driveway on the heel side of the wall in the future.  If I put a 2 ft (highway) surcharge on the heel side of the wall the footing at the will seems to excessively large.  Since the driveway will be to a residence I think the 2 ft of surcharge is excessive, but there may be some short term construction loads that will be larger than passenger vehicles.  I think that a 1 ft surcharge would be fine for the life of the structure.  Anybody out there disagree with using a 1 ft. surcharge?

Thanks,

Joe Grill


---- Msg sent via CableONE.net MyMail - http://www.cableone.net ******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********