Re: Ordinary Truss Moment Frame

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Yeah,

IIRC, there isn't a whole lot out there on STMF's.

Personally, I would be okay with it as you described with the OMEGA LEVEL FORCES and would also make sure the columns, chords and diagonal web members can take OMEGA level forces.

Make sure the block shear is checked at the shear tab at the WF along with coping reductions.

Is this a Staggered Truss System or is this a roof element? The staggered truss system is problematic I believe because of the discontinuity and tranfer diaphragms. I would think that bracing the system out of plane for both top and bottom chords would be important as well.

-g

On 1/17/07, Gary Grinstead <Gary.Grinstead(--nospam--at)ci.stockton.ca.us> wrote:
I have several projects under review where the engineer is using an
Ordinary Moment Frame with trusses for the beam member.  The trusses
consist of WF top chord (single sided shear tab to column with no flange
connection), TS bottom chord, and TS webs (inverted V with a vertical at
midspan).  The connections have been designed for Omega loads (per CBC
2213.6.2).

The question I have is whether this is permitted by the code or must it
be a Special Truss Moment Frame?  Back when I started you'd see these
more frequently though I've usually seen open web joists were used for
the beams.  Since 1988, the UBC added a section regarding trusses in
SMRF and later added the category of Spectial Truss Moment Frame but is
silent regarding the use of trusses in ordinary moment frames.  What
I've found from online searches is also STMF only.  I don't know whether
this is because the extra requirements for Special Truss frames are not
required for Ordinary Truss frames the same way the requirements for
SMRF are not used for OMF.

All opinions will be welcome.





Gary Grinstead
Plancheck Engineer
City of Stockton
(209) 937-5097
Gary.Grinstead(--nospam--at)ci.stockton.ca.us

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********



--
-gm