Lumber Moment Frame Connection

[Subject Prev][Subject Next][Thread Prev][Thread Next]
    Last week a county plan check engineer (Southern California) refused to consider a connection detail using custom steel "T" straps 3/16" thick on both sides - connecting a 6 x 12 beam to a 6 x 6 lumber column ( 2 each 5/8" dia machine bolts in each leg of the "T" Straps).  The lateral force on the simple shed roof 8 foot high patio cover was 2,240 foot- pounds.  
    The plan checker insisted that unless the client would be willing to use bolted lumber "Knee Braces" they would not issue a building permit.  Stating that there is no code approved heavy timber moment frame connection. 
    Your comments please.
 
Jim L. Chatterley PE
Composite Framing Systems, Inc.