Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

Re: Steel Member Check for Seismic Loading

[Subject Prev][Subject Next][Thread Prev][Thread Next]

On May 3, 2007, at 8:15 AM, 남윤호 wrote:

I have the old calculation(1984 made) of steel code check for seismic excitation loading.

In generally steel check for combined bending and axial stress interaction is as follows:
  fa/Fa + fbx/Fbx + fby/Fby < 1.0            -----------(1)
However, the old calculation used the steel check formula under 2 directions horizontal seismic loading(1g each) as follows:
  fa/Fa + root(fbx^2+fby^2)/Fbx < 1.0     -----------(2)

Is it reasonable using equation (2) that steel code checked under 2 directions horizontal seismic loading? If it is reasonable, why do you think using Eq. (2)?
I've never seen your eq 2 specified before, but it's the correct relationship for round sections like pipe. (1) is correct for a section with a rectangular envelope but if you were to use it with pipe you'd get the stress at a 'corner' that doesn't exist. You should work out the algebra for yourself, so you understand what's going on.

Christopher Wright P.E. |"They couldn't hit an elephant at
chrisw(--nospam--at)skypoint.com   | this distance" (last words of Gen.
.......................................| John Sedgwick, Spotsylvania 1864)
http://www.skypoint.com/~chrisw/



******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********