Section 1633.1 requires this for certain types of irregular structures and for columns that are common to the lateral force resisting system in both directions.
 
Ben Yousefi, SE
Santa Monica, CA

________________________________

From: Rand W Holtham [mailto:RHoltham(--nospam--at)CBI.com]
Sent: Wed 5/30/2007 5:56 AM
To: seaint(--nospam--at)seaint.org
Subject: Diagonal base shear UBC 97





In ASCE 7 a structure is to be analyzed with full base shear in one
orthogonal direction and 30% in the other orthogonal direction
simultaneously. Does the UBC-97 have a similar requirement?


TIA,

Rand



******* ****** ******* ******** ******* ******* ******* ***