Re: Roof panel safety factors

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Section 1504.3.2 of IBC 2006 has testing requirements
for metal panel roof systems.

http://roofnav.fmglobal.com/RoofNav/pdf/1-28.PDF and
http://roofnav.fmglobal.com/RoofNav/pdf/1-29.PDF are
Factory Mutual standards that should be useful.  As I
remember FR requires a FS of 2.0 for most roofing
membranes.  Note that the edge of roof and corner
conditions can produce some high uplift values.

******* ****** ******* ******** ******* ******* ******* ***