Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

RE: Question regarding Cracking Moment

[Subject Prev][Subject Next][Thread Prev][Thread Next]
I was debating how best to respond to the question, but since Bill did
such a good job, I no longer feel the need to "debate" nor to answer the
question.

Regards,

Scott
Adrian, MI


On Fri, 15 Jun 2007 William.Sherman(--nospam--at)CH2M.com wrote:

> Here are my thoughts, based on ACI 318-05:
>
> 1. In the Notations and Definitions, the modulus of rupture 'fr' is referenced to 9.5.2.3.  Thus 'fr' is defined in the code as equal to '7.5(f'c)^0.5', regardless of what other references propose.
>
> 2.  'fr' is like 'Ec'; it is a property of the concrete and has the same value regardless of whether applied loads are factored or unfactored.
>
> 3.  It is acceptable to compare service loads with 'fr' or factored loads with 'fr', depending upon the circumstances and goals.
>
> Bill Sherman
> CH2M HILL / DEN
> 720-286-2792
>
>
> ________________________________
>
> From: Anantha Narayan C.K. [mailto:anant_27(--nospam--at)yahoo.com]
> Sent: Thursday, June 14, 2007 3:15 PM
> To: seaint(--nospam--at)seaint.org
> Subject: Question regarding Cracking Moment
>
>
> Folks,
>
> Here is my question once again.
>
> I have questions regarding Cracking moment, Mcr and Modulus of rupture Fr issues with regard to ACI 318.
>
>
> *	R10.11 of ACI 318 says gIf the factored moments and shears from an analysis based on the moment of inertia of a wall taken equal to 0.70 Ig indicate that the wall will crack in flexure, based on the modulus of rupture ccch. My interpretation of this statement in the commentary would lead me to compare the factored moments versus the cracking moment based on the modulus of rupture (which as you stated is a limit state) at strength level.
>
> *	However, 18.3.3 talks about classification based on modulus of rupture at service level forces.
> *	Chapter 14,14.8.2.4 talks about phi Mn > Mcr, where Mcr is given using fr
> *	In his textbook, Dr. McGregor (Page 63, Fourth Edition) states that the 7.5 ffc is used for deflection and 6  ffc is used for strength calculations (ACI 11.4.2.1). In Dr.Wangfs textbook, phi Mn is compared to Mcr. (please see attached file)
>
> As you can clearly see, I am quite confused as to what value of Fr is to be used at service level forces and what value of Fr is to be used at factored forces.
>
> Correct me if I am wrong, shouldnft a limit state such as modulus of rupture be at design level forces (factored)?
>
> I am really hoping that you can help me understand this part of the code.
>
> Also, what are your office standards as far as drift limits for buildings. We typically use H/400 to H/500 for 10 year winds and 3/8" max for interstory drifts. I would love to hear more suggestions/opinions.
>
> Thank you all
> Anantha
>
>
> VTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVTVT
>
> ANANTHA NARAYAN, E.I.
> Structural Engineer
> Bliss and Nyitray Inc.
> Miami, FL - 33134
>
> ________________________________
>
> What kind of emailer are you? Find out today - get a free analysis of your email personality. Take the quiz at the Yahoo! Mail Championship <http://uk.rd.yahoo.com/mail/uk/taglines/default/championships/quiz/*http://uk.rd.yahoo.com/evt=44106/*http://mail.yahoo.net/uk/> .
>

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********