RE: UBC 1630.8.2.2.1.7 Bracing Load

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Title: Strenth and Stiffness of 1x diagonal floor sheathing??

I don’t have the UBC but texts comparing various codes around the world indicate most codes usually adopt a value between 2% and 2.5% of the force in the critical flange.

 

Regards

Conrad Harrison

B.Tech (mfg & mech), MIIE, gradTIEAust

mailto:sch.tectonic(--nospam--at)bigpond.com

Adelaide

South Australia


From: Bill Allen [mailto:T.W.Allen(--nospam--at)cox.net]
Sent: Thursday, 4 October 2007 10:01
To: seaint(--nospam--at)seaint.org
Subject: UBC 1630.8.2.2.1.7 Bracing Load

 

In bracing the top and bottom flange of a steel beam, what force do I use to design the brace connection?

 

TIA,

 

T. William (Bill) Allen, S.E.

ALLEN DESIGNS

Consulting Structural Engineers
 
V (949) 248-8588 F(949) 209-2509