OOP Wall Anchorage - min. size of wood framing member

[Subject Prev][Subject Next][Thread Prev][Thread Next]
1997 UBC Section 1633.2.8.1 required the wood framing member of the wall anchorage assembly in seismic zones 3 and 4 to have a minimum net thickness of 2 1/2".  I do not find this requirement in the 2006 IBC, 2007 CBC, nor in ASCE7-05.  Is this no longer required and, therefore, a 2x member could be used?



******* ****** ******* ******** ******* ******* ******* ***