Re: Gross overturning

[Subject Prev][Subject Next][Thread Prev][Thread Next]
There is none.  For seismic, everything about 1.0 is OK.  I usually use not less than 1.2.
It may be a city policy, then you are out of luck.
 
V. Steve Gordin, SE
Irvine CA
----- Original Message -----
From: Matthew
Sent: Thursday, January 31, 2008 10:08
Subject: Gross overturning

I have a plan check comment stating that a 1.5 F.O.S. is required for gross overturning on any building shear wall from seismic loads at ASD level.  The project is under the 97 UBC; I have been unable to find any code section that requires a 1.5 F.O.S, the only requirement is for earth retaining walls.  Could anyone please comment on where I can find the section?  Or how they have resolved a similar situation?
 
Thank you