Re: Roof Gardens Live load

[Subject Prev][Subject Next][Thread Prev][Thread Next]
I was reading about the ASCE 7 Table 4-1 about the minimum roof loads.

"Roofs used for roof gardens .." 100 psf on page 13 of the book.

Hope that you have not miss this requirement.

//=====

In order to meet the LEED requirements (to get a SILVER) our project
manager insisting on adding a garden on the roof. In a SDC of "E"
building.  In San Jose area near the bay.

Loads 100 psf are not reduceable for seismic design.  How long will it
be for the building owner to recover the cost of adding extera lateral
capacity for a grarden on roof in Bay Area?

Szuchuan

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********