Safety factors for attaching screws to OSB

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Drew,

I use FS of 6 times the load duration factor which comes out close to 4.  This is based on the APA technical note for "Fastener Loads for Plywood - Screws  Number E830C, December 1995".  Tested values for OSB should have a similar factor of safety.

Jared



From: Drew Morris <dmorris(--nospam--at)bbfm.com>
To: SEAINT <seaint(--nospam--at)seaint.org>
Subject: Safety factors for attaching screws to OSB

I have it in my mind that the recommended safety factor for screws in
withdrawal from OSB is a minimum of 4.  Does anyone know what APA
publication lists this?  I have been searching the publications that I
have and cannot find it.  I have a call into APA.

******* ****** ******* ******** ******* ******* ******* ***