3x min for conc/mas wall anch to flex diaph?

[Subject Prev][Subject Next][Thread Prev][Thread Next]

The 1997 UBC Section 1633.2.8.1 item 5 required that wood “elements of anchorage” have the strength to take 0.85 x Fanch and have a minimum net thickness of 2.5 inches.  I am at a loss to find where this requirement is included in the new code.   ASCE 7-05 Section 12.11.2 addresses anchorage of concrete & masonry walls, but the 3x min requirement seems to have been dropped. 

 

I think you would have a hard time finding hardware to fit/work with members smaller than 3x anyway and I plan to continue detailing with 3x minimum.  Just curious if anyone else had noticed this or might have some background on possible reasons for this apparent omission.

 

Regards, 

 

 