RE: Large diameter bolt clearances

[Subject Prev][Subject Next][Thread Prev][Thread Next]
RE: AISC Design Guide 1, Section 2.7.  Provide 1/2" minimum clearance between the washer and the column. 


Regards,
Harold Sprague


From: William.Sherman(--nospam--at)CH2M.com
To: seaint(--nospam--at)seaint.org
Date: Thu, 7 Aug 2008 16:01:28 -0600
Subject: Large diameter bolt clearances

Any suggestions for references for tightening clearance requirements for large diameter anchor bolts (>1.25" diameter)?
 
Bill
William Sherman - CH2M HILL / Denver
Principal Structural Technologist
Structural Global Technology Leader - Water Business Group
720.286.2792
 