RE: Rho, Rho, Rho your boat (foundation)

[Subject Prev][Subject Next][Thread Prev][Thread Next]
25% off on foundation overturning*
========================
* On select structures. See ASCE 12.13.4
 


From: Teo, KP [mailto:KP_Teo(--nospam--at)fwhou.fwc.com]
Sent: Thursday, August 21, 2008 3:52 AM
To: seaint(--nospam--at)seaint.org
Subject: RE: Rho, Rho, Rho your boat (foundation)

If I remember correctly, foundation under the conditions where Rho can be taken as 1.0 is included in California Building Code 1998, which is based on UBC 1997.
It may not be applicable to the code that you're designing to.
 
KP 


From: Jules [mailto:JulesG(--nospam--at)socal.rr.com]
Sent: Wednesday, August 20, 2008 11:11 AM
To: seaint(--nospam--at)seaint.org
Subject: Re: Rho, Rho, Rho your boat (foundation)

I think the wording of the ASCE Section 12.3.4.1 Is not very good. The intent is that ALL conditions should be met for rho =1. Otherwise Section 12.3.4.2 would be contradictory.
 
Jules
----- Original Message -----
Sent: Tuesday, August 19, 2008 9:36 AM
Subject: RE: Rho, Rho, Rho your boat (foundation)

Section 12.3.4.1 of ASCE 7 specifies the conditions where Rho can be assumed to equal 1.0. Foundation is not one of them.

 

Ben Yousefi, SE, CBO

Chief Building Official

City of Mountain View, CA

(650) 526-7007

ben.yousefi(--nospam--at)mountainview.gov


From: Garner, Robert [mailto:rgarner(--nospam--at)moffattnichol.com]
Sent: Tuesday, August 19, 2008 9:22 AM
To: seaint(--nospam--at)seaint.org
Subject: Rho, Rho, Rho your boat (foundation)

 

I'm designing a steel framed structure in Seismic Category D.  For the steel framing, Rho will be 1.3.  For the foundation (a concrete mat foundation), we are using a Rho of 1.0 - our reasoning being that the purpose of Rho is to assure that no single seismic force resisting element above the foundation (the building frames) will likely fail in an earthquake.  Nowhere in the Codes can I find a statement that Rho is to be applied to the foundation.  Can anyone challenge me on this with a Code quote or logical argument?

 

Thanks for any help you can offer.

 

 

Bob Garner, S.E.

 

R. Garner

Moffatt & Nichol

Tel.:  (619) 220-6050

Fax.: (619) 220-6055

e-mail: rgarner(--nospam--at)moffattnichol.com

 

--------------------------------------------------------------------------------------------------------------------------------------