I would replace "All" with "Some" in accordance with CBC 2304.11.2.3. But what you said is commonly followed around here.
 
Suresh Acharya, S.E.


From: Gerard Madden, SE [mailto:gmse4603(--nospam--at)gmail.com]
Sent: Tuesday, September 16, 2008 12:12 PM
To: seaint(--nospam--at)seaint.org
Subject: Re: PT ledger

All structural wood in contact with concrete or CMU should be pressure treated or naturally resistant to decay.

-gm

On Tue, Sep 16, 2008 at 12:00 PM, Tarek Mokhtar <Tarekmokhtar(--nospam--at)earthlink.net> wrote:
Is a ledger supporting a wood floor against a waterproofed basement retaining wall required to
be pressure treated?
--
Tarek Mokhtar, SE








******* ****** ******* ******** ******* ******* ******* ***