Hello Suresh,
 
No even it is a compression zone there we have to design for shear also which reduces the Negetive moment r/f, the action is same like footing design on footing slab, just check for one way shear and punching (two way ) shear and extend the boottom r/f fraction till colum and curtail it...!!!
Regards,
Phani Krishna,
Sr.Design Engineer,     
Larsen&Toubro(L&T),
GES.


From: maryamma suresh(biji) [marymskp(--nospam--at)gmail.com]
Sent: Wednesday, September 17, 2008 1:47 PM
To: seaint(--nospam--at)seaint.org
Subject: drop panel reinfocement

Dear all,
 
Is it necessary to provide bottom minmum  reinforcement  for a drop panel in flat slab with drop panels?  Since it is compression zone I think reinforcement is not required.please tell yours opinion.
 
thanks,
 
Mariyamma suresh
 
Structural Engineer
 
Dubai


"This Message and its contents is intended solely for the addressee and is proprietary.Information in this mail is for L&T Business Usage only. Any Use to other than the addressee is misuse and infringement to Proprietorship of L&T ECC.If you are not the addressee please return the mail to the sender.L&T ECC DIVISION"