Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

RE: Curved GluLam tie

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Title: Curved GluLam tie

Mark,

 

ARCH doesn’t want double tension rods, but I like your idea.  I’ll use it in the future.

 

thanks,

Gordon Goodell

 

From: Mark D. Baker [mailto:shake4bake(--nospam--at)verizon.net]
Sent: Monday, October 13, 2008 11:28 AM
To: seaint(--nospam--at)seaint.org
Subject: RE: Curved GluLam tie

 

Try using double tie rods with Simpson PHD’s, or HD’s or similar connectors on each side of the glu-lam.

 

Mark Baker

 


From: Gordon Goodell [mailto:GordonGoodell(--nospam--at)harmonydesigninc.com]
Sent: Monday, October 13, 2008 8:50 AM
To: seaint(--nospam--at)seaint.org
Subject: Curved GluLam tie

 

Good morning,

I’m looking for a good connection between a curved glulam roof member and ¾” steel tie rod at the base (@ wall line).  It’s ~8 kips.  I’d like to drill all the way through and use a bearing plate, but that’s about a 2’ long hole.  Any ideas?

 

thanks,

Gordon Goodell


ExchangeDefender Message Security: Check Authenticity