Re: Steel Joist Seat Height

[Subject Prev][Subject Next][Thread Prev][Thread Next]
We will call out 8K1 and 10K1 joists where applicable either for roof or floor framing.  From SJI, the K joists will have 2 1/2" seats and LH joists will have 5" seats.  When the joists are not flat, then you have to look at the minimum seat depth so the joist will clear the edge of the CMU block wall or W beam flange edge.

Gary L. Hodgson and Assoc. wrote:
List,
In this area (southern Ontario), all standard joists had 2.5" shoes at one time, until people found too many joists had the diagonals hitting the block wall or beam flange and there was a movement to change the standard shoe depth to 4".  There is still the odd engineer out there dwelling in the past who still specs 2.5" shoes.  Now there is a push to use standard joist shoes of 5" depth.
Aside from that, does anybody specify 8" or 10" joists these days?  It seems the labour costs are too high, compared to using light hot rolled WF beams or channels, or cold rolled members (some with web holes).
Gary

Haan, Scott M POA wrote:
I've had Vulcraft engineers tell me they wanted the low end 5.5" tall for
sloped joists I am laying out now.  Different than what is shown in the
catalog.  They will give you what you spec.  Call and ask what they can
provide.

-----Original Message-----
From: Paul Blomberg [mailto:paul.blomberg(--nospam--at)gmail.com] Sent: Wednesday, March 25, 2009 7:17 AM
To: seaint(--nospam--at)seaint.org
Subject: Steel Joist Seat Height

I need a sanity check on a 2:12 sloped LH joist seat height.  As I'm not
really a joist guy I appreciate the help.  The Vulcraft catalog has the high
end joist seat depth at 7".  But the low end seat depth is " 6" min.* ".
 
I'm assuming that the the seats depths will be the same at both ends, in this
case 7".  Is this correct?   
Paul.
 
 

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* *   This email was sent to you via Structural Engineers *   Association of Southern California (SEAOSC) server. To *   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you *   send to the list is public domain and may be re-posted *   without your permission. Make sure you visit our web *   site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********
 

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* *   This email was sent to you via Structural Engineers *   Association of Southern California (SEAOSC) server. To *   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you *   send to the list is public domain and may be re-posted *   without your permission. Make sure you visit our web *   site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********