Re: Concrete Fix - Manure Storage Slab

[Subject Prev][Subject Next][Thread Prev][Thread Next]
SGE Structural wrote:
Mark,
 
A 4" overlay does not appear sufficient for the given heavy equipment and the environment, and is likely to crack again. A thicker overlay with doweled rebars monolithically poured over the original (leaking) cold joint may effectively prevent leaks even without waterstops.  You may also consider the necessity of the control joints.
 

Steel-Fiber reinforcement (e.g. "Dramix"), either through the slab or in a thick topping.
******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********