Point load on garage diaphram

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Designing a residential garage floor system. Wood framing, Lt-weight concrete over plywood. To design this to code a 3k pt load must be placed on an area 4.5 x 4.5 inches. After designing the joists & beams for this load I now must design the plywood spaning btw'n the joists for the 3k pt load placed at mid-span. 

Even at 8" o.c. joist spacing & 1-1/8" Struct I plywood:

Max moment is 6.0 k-in & the allowable bending stress is 1650psi. Based on this I will need 1-5/8" thick plywood.  Am I missing something?


******* ****** ******* ******** ******* ******* ******* ***