Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

Deformed bars - Permissible variation in weight

[Subject Prev][Subject Next][Thread Prev][Thread Next]

We have a situation where the test results give under weight bars (approx 15%), exceeding the 6% permissible variation in weight by ASTM. If we account for the reductions in weight/diameter by decreasing spacings and providing ample steel area, is there any codal provision restricting it.

 

Best regards,

Shiraz Shahid.