RE: Deflection

[Subject Prev][Subject Next][Thread Prev][Thread Next]

I’ve typically seen people use H/400 for code-level (50-yr) wind or H/500 for 10-yr wind.  These end up being pretty close to the same.  AISC Design Guide 3 has some guidance.

 

-- Joel Adair

    SHW Group

    Dallas, TX

 

From: Doug Mayer [mailto:doug.mayer(--nospam--at)taylorteter.com]
Sent: Wednesday, November 04, 2009 2:15 PM
To: seaint(--nospam--at)seaint.org
Subject: Deflection

 

When wind governs in your lateral system design, what is the building drift limitation?  There doesn’t seem to be any specified building drift limitation for wind loads (that I can find) in the code.  What do you wind country folks do?

 

Thanks,

 

Doug Mayer, SE

 

NOTICE:
This e-mail transmission is intended only for the use of the individual or entity named above and may contain information that is confidential, privileged, and/or exempt from disclosure under applicable law. If you are not the intended recipient, you are hereby notified that any review, disclosure, copying, distribution, or other use of any of the information contained in this transmission is strictly prohibited. If you have received this transmission in error, please immediately notify the sender by e-mail at the above address and delete it from your computer system; you should not copy the message or disclose its contents to anyone. The content of the message and or attachments may not reflect the view and opinions of the originating company or any party it is representing.