Gary,
It is just the weight of the volume of displaced concrete at 145 pcf.  It is easier to use multiple lifts so that there is less volume displaced for any given lift thus reducing the tie-down demand. 
 
I was going to develop this priciple myself, but Archimedes edged me out by about 2200 years.  In geologic terms it was a dead heat.  http://en.wikipedia.org/wiki/Buoyancy 

Regards, Harold Sprague


 
> Date: Thu, 15 Apr 2010 13:34:39 -0400
> From: design(--nospam--at)hodgsoneng.ca
> To: seaint(--nospam--at)seaint.org
> Subject: Uplift Pressure of Wet Concrete?
>
> List,
>
> I'm currently working with some 1980mm (78" dia.) penstocks at an old
> hydro plant that are being renovated or replaced.
>
> I have to design the temporary tie-downs at the thrust blocks or support
> points when they pour concrete around them. I did a similar project
> about 15 years ago but I can't find my reference material.
>
> Does anybody know the uplift pressure (buoyancy) of wet concrete?
>
> Gary
>
>
> ******* ****** ******* ******** ******* ******* ******* ***
> * Read list FAQ at: http://www.seaint.org/list_FAQ.asp
> *
> * This email was sent to you via Structural Engineers
> * Association of Southern California (SEAOSC) server. To
> * subscribe (no fee) or UnSubscribe, please go to:
> *
> * http://www.seaint.org/sealist1.asp
> *
> * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
> * send to the list is public domain and may be re-posted
> * without your permission. Make sure you visit our web
> * site at: http://www.seaint.org
> ******* ****** ****** ****** ******* ****** ****** ********


The New Busy is not the old busy. Search, chat and e-mail from your inbox. Get started.