The beams are taken from the AISC 6th Edition, last revised in 1964

BTW, can’t find “WF12x92” in my handbook (Canadian)
 
From: Thor Tandy [mailto:vicpeng(--nospam--at)telus.net]
Sent: Wednesday, February 02, 2011 1:26 PM
To: 'seaint(--nospam--at)seaint.org'
Subject: RE: Beam Nominations
 
Yes, thanks.
 
I made a mistake on the second beam
 
12"x12"  Web 5/8"  Flange  7/8" should have been 12”x14”
 
 



14"x12"  Web 5/8"  Flange  7/8"
The nearest sizes in this book are:
WF14x12x78 D=14", Wf=12", tf=11/16", tw=7/16", Ix=851.2in^4, Sx=121.1in^3, rx=6.09", 
Iy=206.9in^4, Sy=34.3^3, ry=3.00"
WF14x12x84 D=14.1/8", Wf=12", tf=3/4", tw=7/16", Ix=928.4in^4, Sx=130.9in^3, rx=6.13", 
Iy=225.5in^4, Sy=37.5^3, ry=3.02"
 
I hope this helps.
Stephen Macie, P.E.