RE: 2013 Codes

[Subject Prev][Subject Next][Thread Prev][Thread Next]
I can appreciate the attitude.  In Florida we've been using ASCE 7-10 for 
quite a while.  (I submitted a somewhat sarcastic post to this board 
several months ago about trying to explain to architects why wind on a 
hospital is faster than it is on an office building.  My email didn't 
convey the sarcasm very well, and got some serious replies.)

Regarding the code itself:  It's almost as though ASCE added another entire 
 wind chapter to save you the trouble of multiplying by 1.15.  (That was a 
little bit sarcastic also.)

Regards,
Carl W. Jenne, P.E.
Allan and Conrad, Inc.
Consulting Structural Engineers
Ring 407.628.5282 x 102
www.acstructural.com


.

-----Original Message-----
From: seaint-seaosc(--nospam--at)mail-list.com [mailto:seaint-seaosc(--nospam--at)mail-list.com] On 
Behalf Of Joel Adair Sent: Wednesday, November 06, 2013 3:48 PM
To: seaint-seaosc(--nospam--at)mail-list.com
Subject: RE: [SEAINT-SEAOSC] 2013 Codes

Last year, I did a project in Odessa, TX, where they had already adopted 
IBC 2012, and hence, ASCE 7-10.  At the time, RAM Structural System hadn't 
incorporated the new wind provisions, so I did a little exercise to compare 
 the results of the new method -- with wind pressures calculated at 
ultimate levels, then used in load combinations with a factor of 1.0 for 
LRFD or 0.6 for ASD -- versus the old method.  In the end, the new method 
resulted in forces about 4% lower than the old method for my particular 
case.  In other words, you wind up at essentially the same place, but take 
a completely different path to get there.  I used the software-generated 
wind forces, based on ASCE 7-05 and went about my business.

It sure threw off the curtain wall manufacturer, though.  Their engineer 
was making a fuss about how my general notes required them to design for 
120 mph, when they've been using 90 mph for years.  I had to explain that 
he needs to use the new code, that 120 mph produces an ULTIMATE-level wind 
pressure, and that in the end, their design should come out about the same 
as what they've done in the past.  I think it took him a while to get his 
head wrapped around it.

I'm not sure what the impetus was for the changes in the wind code, but I'm

Truncated 1104 characters in the previous message to save energy.

-------------------------------------------------------------------------
Post your message to the list by sending it to: 
   SEAINT-SEAOSC(--nospam--at)mail-list.com.

The email messages sent to the list will be saved in an archive on the World Wide Web.
These archives are located at:
    http://archive.mail-list.com/SEAINT-SEAOSC

To contact the list owner, send your message to:
   SEAINT-SEAOSC-list-owner(--nospam--at)mail-list.com.

Sponsored By: Pacific Structural & Forensic Engineers Group, Inc. (PSFEG)

To unsubscribe, switch to/from digest, get on/off vacation, or change your email address, click here.
<http://cgi.mail-list.com/u?ln=seaint-seaosc&nm=seaintma%40euken.net>